Induction magnetometric sensor IMD-100

Special geophysical systems

Induction magnetometric sensor IMD-100

 

INDUCTION MAGNETOMETRIC SENSOR

IMD-100

датчик индукционный магнитометрический

The IMD-100 sensors are designed to measure magnetic components of the electromagnetic field during electrical exploration geophysical work as part of the AGE-xxl complex with AGE-xxl-24-MX measuring devices.

The sensor consists of an induction magnetometric transducer (IMT) enclosed in a sealed housing containing bubble levels for vertical and horizontal installation of the sensor in the research area.

Technical specifications

Parameter name

Typical value

Conversion coefficient of IMP, Kimp, mV/nT Hz
(effective area, m2)

0,01±0,001

(1590)

Frequency range (linearly increasing part of frequency response), Hz

0.01-500

Terms of Use:

 

- relative air humidity, at a temperature of up to 35°C

up to 98%

- ambient temperature

from minus 40 °C to 70 °C

Dimensions of the sensor, no more than

- diameter, mm

- length, mm

 

64

830

Sensor weight, kg, no more than

6

Frequency response and phase response of the IMP converter.

(Along the X axis, frequency, Hz; along the Y1 axis, output voltage, rel. units, ; along the Y2 axis – phase, in degrees).

Spectral density of the root-mean-square value of the noise level UNrms of the IMD-100 sensor