Accelerometers for monitoring the operation of pulsed seismic sources

Special geophysical systems

Accelerometers for monitoring the operation of pulsed seismic sources

Accelerometers for monitoring the operation of pulsed seismic sources

ACCELEROMETER ANALOGUE

Designed for use as part of monitoring equipment for the operation of various pulsed sources of excitation of seismic vibrations. The accelerometer generates an output signal proportional to the force on the working elements of the sources during seismic surveys.

In terms of resistance to climatic effects, it corresponds to group 5 according to GOST 22261-82.
 

 

Specifications

Name

Value

Sensitivity of the primary converter, mV / g, (optional)

18 ± 1,5

8 ± 1.4

Dynamic range, g, not less (optional)

± 105

± 210

Nonlinearity,%

0.2

Transverse sensitivity,%

± 2

Operating frequency band, Hz, at -3dB

0-400

Supply voltage

5 ± 0.25

Consumed current, mA, no more

2

Overall dimensions of the sensor, mm, no more

70x46x46

Weight, kg, no more

0.2

 

ACCELEROMETER DIGITAL

Designed for use as part of monitoring equipment for the operation of various pulsed sources of excitation of seismic vibrations. It differs from an analog device by an interference-proof digital channel for transmitting information to the synchronization system of seismic sources .

In terms of resistance to climatic influences, it corresponds to group 5 according to GOST 22261-82.

 

Specifications

Name

Value

Sensitivity of the primary converter, mV / g, (optional)

18 ± 1,5

8 ± 1.4

Dynamic range, g, not less (optional)

± 105

± 210

Nonlinearity,%

0.2

Transverse sensitivity,%

± 2

Operating frequency band, Hz, at -3dB

0-400

Digitization of acceleration digitization, bit

12

Quantization frequency, Hz

1500

Information transfer rate, bit / s

115,000

Supply voltage

from 7 to 24

Consumed current, mA, no more

fifteen

Overall dimensions of the sensor, mm, no more

120x46x46

Weight, kg, no more

0.3